We provide wide range of customized Li-ion Battery Pack. You can find any range of battery pack with us. 12V, 24V, 36V, 48V, 60, 72V, 96V etc. These batteries used in 2 Wheel, 3 Wheel, and 4 Wheel Vehicles well as other related projects.
Battery Type: Li-Ion, FeLiO4P Warranty: 6-12 Months
Customization: Yes (As per Your requirement)
Hi-Kraft (BIS Approved Cell).
Descriptions:
- Brand: Hi-Kraft
- Nominal Voltage: 3.7V
- Nominal Capacity: 2600mAh
- Battery type: LiFePo4
- Charge current: 100.0A
- Internal resistance: <0mΩ
- Maximum charging voltage: 3.75 + -0.05V
- Continuous discharge current: 100A
- Maximum pulse discharge current: 3C
- Discharge Cut-off voltage: 2.0V
- Cell weight: 2250g average
- Life cycles: More than 2000 times
- Dimensions (mm): 37(thickness) x 131(width) x 2700mm (length excluding Lugs
Applications:
Widely used battery, electric vehicles, model aircraft, electric tools, Golf carts, sightseeing coaches, electric Motorcycles, electric bicycles. Batteries pack diy, inverter battery, outdoor high power lithium battery pack.
PCM Specifications For 59.2V (16S) LiFePo4 Battery Packs | |||
Model: LWS-16S150A | |||
No. | Test Item | Criterion | |
1. | Voltage | Charging Voltage for single cell | DC:67.2V 3.7/Cell |
Balance voltage for single cell | 4.2V+0.025V | ||
2. | Current | Balance current for single cell | 42mA+5mA |
Current Consumption | <25uA | ||
Maximal continuous charging current | 150A | ||
Maximal continuous discharging current | 150A | ||
3. | Over charge protection | Over charge detection voltage for single cell | 4.25V+0.025V |
Over charge detection delay time | 800-1300mS | ||
Over charge release voltage for single cell | 4.05+0.05V | ||
4. | Over Discharge protection | Over discharge detection voltage for single cell | 2.50V+0.0625V |
Over discharge detection delay time | 100-1800mS | ||
Over discharge release voltage for single cell | 3.00+0.075V | ||
5. | Over current protection | Over current detection voltage | 100+25mv |
Over current detection current | 350+50A | ||
Detection delay time | 800-1300mS | ||
Release condition | Cut Load | ||
6. | Short Protection | Detection Condition | Exterior short circuit |
Detection delay time | 50-200us | ||
Release condition | Cut load | ||
7. | Resistance | Protection Circuity (MOSFET) | <60mΩ |
8. | Temperature | Protection Temperature | 75°C+5°C |
Temperature Release | 50.5°C + 12.5°C | ||
Operating Temperature Range | -40~+85°C | ||
Storage Temperature Range | -40~+125°C |
PCM Specifications For 59.2V (16S) LiFePo4 Battery Packs | |||
Model: LWS-16S120A | |||
No. | Test Item | Criterion | |
1. | Voltage | Charging Voltage for single cell | DC:67.2V 3.7/Cell |
Balance voltage for single cell | 4.2V+0.025V | ||
2. | Current | Balance current for single cell | 42mA+5mA |
Current Consumption | <25uA | ||
Maximal continuous charging current | 120A | ||
Maximal continuous discharging current | 120A | ||
3. | Over charge protection | Over charge detection voltage for single cell | 4.25V+0.025V |
Over charge detection delay time | 800-1300mS | ||
Over charge release voltage for single cell | 4.05+0.05V | ||
4. | Over Discharge protection | Over discharge detection voltage for single cell | 2.50V+0.0625V |
Over discharge detection delay time | 100-1800mS | ||
Over discharge release voltage for single cell | 3.00+0.075V | ||
5. | Over current protection | Over current detection voltage | 100+25mv |
Over current detection current | 350+50A | ||
Detection delay time | 800-1300mS | ||
Release condition | Cut Load | ||
6. | Short Protection | Detection Condition | Exterior short circuit |
Detection delay time | 50-200us | ||
Release condition | Cut load | ||
7. | Resistance | Protection Circuity (MOSFET) | <60mΩ |
8. | Temperature | Protection Temperature | 75°C+5°C |
Temperature Release | 50.5°C + 12.5°C | ||
Operating Temperature Range | -40~+85°C | ||
Storage Temperature Range | -40~+125°C |
PCM Specifications For 59.2V (16S) LiFePo4 Battery Packs | |||
Model: LWS-16S100A | |||
No. | Test Item | Criterion | |
1. | Voltage | Charging Voltage for single cell | DC:67.2V 3.7/Cell |
Balance voltage for single cell | 4.2V+0.025V | ||
2. | Current | Balance current for single cell | 42mA+5mA |
Current Consumption | <25uA | ||
Maximal continuous charging current | 100A | ||
Maximal continuous discharging current | 100A | ||
3. | Over charge protection | Over charge detection voltage for single cell | 4.25V+0.025V |
Over charge detection delay time | 800-1300mS | ||
Over charge release voltage for single cell | 4.05+0.05V | ||
4. | Over Discharge protection | Over discharge detection voltage for single cell | 2.50V+0.0625V |
Over discharge detection delay time | 100-1800mS | ||
Over discharge release voltage for single cell | 3.00+0.075V | ||
5. | Over current protection | Over current detection voltage | 100+25mv |
Over current detection current | 350+50A | ||
Detection delay time | 800-1300mS | ||
Release condition | Cut Load | ||
6. | Short Protection | Detection Condition | Exterior short circuit |
Detection delay time | 50-200us | ||
Release condition | Cut load | ||
7. | Resistance | Protection Circuity (MOSFET) | <60mΩ |
8. | Temperature | Protection Temperature | 75°C+5°C |
Temperature Release | 50.5°C + 12.5°C | ||
Operating Temperature Range | -40~+85°C | ||
Storage Temperature Range | -40~+125°C |
PCM Specifications For 48.1V (13S) LiFePo4 Battery Packs | |||
Model: LWS-13S 150A | |||
No. | Test Item | Criterion | |
1. | Voltage | Charging Voltage for single cell | DC:54.6V CC/CV |
Balance voltage for single cell | 4.2V+0.025V | ||
2. | Current | Balance current for single cell | 42mA+5mA |
Current Consumption | <25uA | ||
Maximal continuous charging current | 150A | ||
Maximal continuous discharging current | 150A | ||
3. | Over charge protection | Over charge detection voltage for single cell | 4.25V+0.025V |
Over charge detection delay time | 800-1300mS | ||
Over charge release voltage for single cell | 4.05+0.05V | ||
4. | Over Discharge protection | Over discharge detection voltage for single cell | 2.50V+0.0625V |
Over discharge detection delay time | 1000-1800mS | ||
Over discharge release voltage for single cell | 3.00+0.075V | ||
5. | Over current protection | Over current detection voltage | 200+25mv |
Over current detection current | 350+20A | ||
Detection delay time | 800-1300mS | ||
Release condition | Cut Load | ||
6. | Short Protection | Detection Condition | Exterior short circuit |
Detection delay time | 50-200us | ||
Release condition | Cut load | ||
7. | Resistance | Protection Circuity (MOSFET) | <20mΩ |
8. | Temperature | Protection Temperature | 75°C+5°C |
Operating Temperature Range | -40~+85°C | ||
Storage Temperature Range | -40~+125°C |
PCM Specifications For 48.1V (13S) LiFePo4 Battery Packs | |||
Model: LWS-13S 100A | |||
No. | Test Item | Criterion | |
1. | Voltage | Charging Voltage for single cell | DC:54.6V CC/CV |
Balance voltage for single cell | 4.2V+0.025V | ||
2. | Current | Balance current for single cell | 42mA+5mA |
Current Consumption | <25uA | ||
Maximal continuous charging current | 100A | ||
Maximal continuous discharging current | 100A | ||
3. | Over charge protection | Over charge detection voltage for single cell | 4.25V+0.025V |
Over charge detection delay time | 800-1300mS | ||
Over charge release voltage for single cell | 4.05+0.05V | ||
4. | Over Discharge protection | Over discharge detection voltage for single cell | 2.50V+0.0625V |
Over discharge detection delay time | 1000-1800mS | ||
Over discharge release voltage for single cell | 3.00+0.075V | ||
5. | Over current protection | Over current detection voltage | 200+25mv |
Over current detection current | 350+20A | ||
Detection delay time | 800-1300mS | ||
Release condition | Cut Load | ||
6. | Short Protection | Detection Condition | Exterior short circuit |
Detection delay time | 50-200us | ||
Release condition | Cut load | ||
7. | Resistance | Protection Circuity (MOSFET) | <20mΩ |
8. | Temperature | Protection Temperature | 75°C+5°C |
Operating Temperature Range | -40~+85°C | ||
Storage Temperature Range | -40~+125°C |
PCM Specifications For 48.1V (13S) LiFePo4 Battery Packs | |||
Model: LWS-13S 40A | |||
No. | Test Item | Criterion | |
1. | Voltage | Charging Voltage for single cell | DC:54.6V CC/CV |
Balance voltage for single cell | 4.2V+0.025V | ||
2. | Current | Balance current for single cell | 42mA+5mA |
Current Consumption | <25uA | ||
Maximal continuous charging current | 40A | ||
Maximal continuous discharging current | 40A | ||
3. | Over charge protection | Over charge detection voltage for single cell | 4.25V+0.025V |
Over charge detection delay time | 800-1300mS | ||
Over charge release voltage for single cell | 4.05+0.05V | ||
4. | Over Discharge protection | Over discharge detection voltage for single cell | 2.50V+0.0625V |
Over discharge detection delay time | 1000-1800mS | ||
Over discharge release voltage for single cell | 3.00+0.075V | ||
5. | Over current protection | Over current detection voltage | 200+25mv |
Over current detection current | 350+20A | ||
Detection delay time | 800-1300mS | ||
Release condition | Cut Load | ||
6. | Short Protection | Detection Condition | Exterior short circuit |
Detection delay time | 50-200us | ||
Release condition | Cut load | ||
7. | Resistance | Protection Circuity (MOSFET) | <20mΩ |
8. | Temperature | Protection Temperature | 75°C+5°C |
Operating Temperature Range | -40~+85°C | ||
Storage Temperature Range | -40~+125°C |